Appareil de tomodensitométrie à rayons X YSCT-32D

Item No.: YSCT-32D
The X-ray source assembly rotates 360°, and the maximum number of scan layers that can be obtained in a single axial scan is 32.
Scan mode: positioning scan, tomographic scan, spiral scan, enhanced scan, perfusion scan.
Product parameters
Brand: YSENMED
MOQ: 1
Package: Wooden Package
Ship From: Guangzhou
Lead Time: 3-15 days
Customization: Customized package

Description

Parameters

Part name  Model Specifications
Scanning frame SM100 Scanning frame aperture: 700mm±10mm
Scanning frame rotation speed: 0.75s, 1.0s, 1.5s, 2.0s
Scanning field of view: 430mm
Type of Slip ring: contact slip ring
High voltage generator CT70PN32X5610 Tube voltage setting: 70~140kV
Tube current range: 10~300mA
Nominal output power: 32kW
Collimator CMT-003 Half value layer:≥4.6mmAl
Equivalent aluminum equivalent thickness:2.3mmAl
X-ray tube sleeve B-240H Nominal tube voltage: 140kV
Nominal anode input power: 29kW/48kW
Maximum continuous heat dissipation of anode: 3.5kW
Focus size:
0.7mm ×0.8mm
1.2mm ×1.4mm
Anode rotation speed: 60Hz/180Hz
Diameter of anode target surface (mm): 140mm
Target angle: 7°
Anode type: rotating anode
Bearing type: mechanical bearing
Quantity (pcs): 1
Fly focus (x to z offset): none
The longest spiral scanning time: 100s
Anode heat capacity:3.5MHU
X-ray tube GS-30722
Detector DET-003 Scintillation crystal material: GOS crystal
Pixel matrix: 704×16
Number of detectors: 11
Coverage (projected to the center of rotation): 430mm
Pixel size (projected to the center of rotation) 1.25mm × 1.25mm
Scanning angle: 0°/90°
Scanning field of view: 430mm
Axial scanning layer thickness: 1.25 mm ± 0.625 mm, 2.50 mm ± 1.0 mm, 5.00 mm ± 1.0 mm, 10.0 mm ± 1.0 mm;
Spiral scanning layer thickness: 1.25 mm ± 0.625 mm, 2.50 mm ± 1.0 mm, 3.75 mm ± 1.0 mm, 5.00 mm ± 1.0 mm, 7.50 mm ± 1.0 mm, 10.0 mm ± 1.0 mm;
Collimation combination: 16×1.25, 4×1.25;
Diagnostic bed ZC300 Z-axis positioning accuracy (mm): ≤±1mm
Speed: 0~150mm/s
Vertical lifting range: ≥440mm
Maximum load: 205kg
Laser M63AXSAXX-XX Category: 2 types
Positioning accuracy: ±1mm
Wavelength: 600~700nm
Maximum output power: <1mW
Console
CZ100
KH100 Control box:
Exposure control
Bed motion control
Intercom function
/ Computer
The minimum configuration requirements are as follows
CPU performance: the main frequency is not less than 2 GHz, the number of cores is not less than 2 cores
Memory size: no less than 8GB
Image storage capacity: no less than 850GB
/ Monitor
The minimum configuration requirements are as follows
Screen resolution: 1920×1200 SXGA
Number of displays size: 1*24 inches
Type: LCD, color
Contrast ratio: 1000:1
Preview
Computer image processing software ScintVue Release version: 1.0

The X-ray source assembly rotates 360°, and the maximum number of scan layers that can be obtained in a single axial scan is 32.
Maximum scanning range: 1200mm
Pitch coefficient: 0.25, 0.5, 0.75, 1, 1.25, 1.5, 1.75
Scan mode: positioning scan, tomographic scan, spiral scan, enhanced scan, perfusion scan

Software function
Patient file management
Patient registration
Scan function
reconstruction
2D image browsing and processing
3D image browsing and processing
Film printing
Data management function

1